• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Medical Journal of Viral Hepatitis
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 9.1 (2025)
Volume Volume 8.2 (2024)
Volume Volume 8.1 (2024)
Volume Volume 7.3 (2023)
Volume Volume 7.2 (2023)
Volume Volume 7.1 (2022)
Volume Volume 6.3 (2022)
Volume Volume 6.2 (2022)
Volume Volume 6.1 (2021)
Volume Volume 5.3 (2021)
Volume Volume 5.2 (2021)
Volume Volume 5.1 (2020)
Volume Volume 4.2 (2020)
Volume Volume 4.1 (2019)
Volume Volume 3.2 (2019)
Volume Volume 3.1 (2018)
Volume Volume 2.2 (2018)
Volume Volume 2.1 (2016)
Issue Issue 1
Volume Volume 1.2 (2016)
Volume Volume 1.1 (2015)
G., S., S., E., M., B., M., H., M, E., EA., G., K., Z., R., S., M., E., NNH., M. (2016). Comparison between Transient Elastography (FibroScan) and Liver Biopsy for the Diagnosis of Hepatic Fibrosis in Chronic Hepatitis C Patients. Medical Journal of Viral Hepatitis, 2.1(1), 1-9. doi: 10.21608/mjvh.2016.4571
Shiha G.; El-Etreby S.; Bahgat M.; Hamed M.; El Sherbini M; Ghoneem EA.; Zalata K.; Soliman R.; El-Basiouny M.; Mikhail NNH.. "Comparison between Transient Elastography (FibroScan) and Liver Biopsy for the Diagnosis of Hepatic Fibrosis in Chronic Hepatitis C Patients". Medical Journal of Viral Hepatitis, 2.1, 1, 2016, 1-9. doi: 10.21608/mjvh.2016.4571
G., S., S., E., M., B., M., H., M, E., EA., G., K., Z., R., S., M., E., NNH., M. (2016). 'Comparison between Transient Elastography (FibroScan) and Liver Biopsy for the Diagnosis of Hepatic Fibrosis in Chronic Hepatitis C Patients', Medical Journal of Viral Hepatitis, 2.1(1), pp. 1-9. doi: 10.21608/mjvh.2016.4571
G., S., S., E., M., B., M., H., M, E., EA., G., K., Z., R., S., M., E., NNH., M. Comparison between Transient Elastography (FibroScan) and Liver Biopsy for the Diagnosis of Hepatic Fibrosis in Chronic Hepatitis C Patients. Medical Journal of Viral Hepatitis, 2016; 2.1(1): 1-9. doi: 10.21608/mjvh.2016.4571

Comparison between Transient Elastography (FibroScan) and Liver Biopsy for the Diagnosis of Hepatic Fibrosis in Chronic Hepatitis C Patients

Article 3, Volume 2.1, Issue 1, November 2016, Page 1-9  XML PDF (191.61 K)
Document Type: Original article
DOI: 10.21608/mjvh.2016.4571
View on SCiNiTO View on SCiNiTO
Authors
Shiha G.1; El-Etreby S.2; Bahgat M.2; Hamed M.2; El Sherbini M2; Ghoneem EA.3; Zalata K.4; Soliman R.5; El-Basiouny M.1; Mikhail NNH.6
1Egyptian Liver Research Institute and Hospital (ELRIH), Sherbin, El-Mansoura, Egypt, Hepatology & Gastroenterology unit, Internal Medicine Department, Faculty of Medicine,El-Mansoura University, Egypt
2Hepatology & Gastroenterology unit, Internal Medicine Department, Faculty of Medicine,El-Mansoura University, Egypt
3Hepatology & Gastroenterology unit, Internal Medicine Department, Faculty of Medicine, El-Mansoura University, Egypt
4Pathology Department, Faculty of Medicine, El-Mansoura University, Egypt
5Egyptian Liver Research Institute and Hospital (ELRIH), Sherbin, El-Mansoura, Egypt
6Egyptian Liver Research Institute and Hospital (ELRIH), Sherbin, El-Mansoura, Egypt,Department of Biostatistics, South Egypt Cancer Institute, Assiut University, Egypt
Abstract
Transient elastography (TE) is gaining popularity as a non-invasive method for predicting liver fibrosis. The practical utility of the method is based on establishing cutoff values for each stage of fibrosis. A diagnosis of stage is based on measurements of liver stiffness that vary in different studies. The present study aimed to establish cutoff values for each stage of fibrosis to assess the performance of TE in fibrosis staging in Egyptian chronic HCV patients. This cross-sectional study was conducted at Specialized Medical Hospital and the Egyptian Liver Foundation, Mansoura, Egypt. The inclusion
criteria were: age older than 18 years and chronic infection by hepatitis C. The exclusion criteria were the presence of ascites, pacemaker or pregnancy. Three hundred and fifty six consecutive patients with chronic hepatitis C participated in the study. Liver fibrosis was staged according to the METAVIR system. The AUROCs for F2 or greater, F3 or greater and cirrhosis (F4) were 0.91 (95% CI 0.87 to 0.94), 0.95 (95% CI 0.91 to 0.99) and 0.97 (95% CI 0.96 to 0.99), respectively. ROC curve analysis identified optimal cutoff value of liver stiffness measurements as high as 9.8 kPa for F ≥ 2, 10.4 kPa for F ≥ 3, and 17.2 kPa for F = 4. The overall relation between fibrosis stages when comparing both FibroScan and biopsy was significant agreement between both (the kappa measure was 0.430 and p<0.001). TE is a good non-invasive
tool for diagnosis and monitoring of liver fibrosis among patients with Chronic HCV infection.
Keywords
Transient elastography; FibroScan; Liver Biopsy; Chronic hepatitis C
Statistics
Article View: 1,072
PDF Download: 686
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.